Item # 5095
Operation:
Depress and hold the ARM button to activate unit. LED will illuminate with a steady on indication. While maintaining pressure on the ARM button, depress the CHARGE/FIRE button for approximately 1-2 seconds. LED will blink to indicate ready status. While maintaing pressure on the ARM button release the CHARGE/FIRE button.
To Abort:
At any time during arm, charge, fire sequence release pressure on the ARM button. Unit will power down and return to safe mode.
Case Material: Urethane Plastic
Case Size: 3"W x 1.5"D x 4"H
Weight: Approximately 14 oz.
Shock Tube Connector: Replaceable
Switch Guards: Protected Push Buttons
Minimum Firing Voltage: 2500VDC
Minimum Firing Energy: .5 joules
Charge/Firing Cycle: 2 seconds
Power Source: Alkaline 9V Battery
MANUFACTURER LIMITED LIFETIME WARRANTY