| FIRING ENERGY: |
450VDC @ 5.0Joules |
| FIRING CAPABILITY: |
Electric Blasting Caps, Electric Breech |
| FIRING CAPACITY: |
250 Ohms circuits requiring minimum 1.5A @ 20mJ/Ohm of resistance |
| FIRE CIRCUIT: |
Locked out unless full charge is available |
| ARMED INDICATOR: |
High visibility green LED |
| LEAD LINE RESISTANCE DETECTION |
| DETECTION: |
Immediate indication of load resistance |
| TEST SIGNAL: |
2.3mA(0.0023A), Fuse Protected |
| INDICATION: |
Green 0-150 Ohms |
| |
Amber 151-250 Ohms |
| |
Red 251+ Ohms |
| NON-ELECTRIC INITIATION |
| FIRING ENERGY: |
2,500 VDC @ 0.5 Joules |
| FIRING CAPACITY: |
1 Non -Electric Shock Tube Line |
| CONNECTION: |
Replaceable Shock Tube Connector (STC ) |
| TYPE: |
EIT STC -E (Electrode In Tube ) |
| SAFETY |
| ELECTRIC OUTPUT: |
Binding Posts shunted internally |
| ELECTRIC ABORT: |
Safe internal discharge when ‘Charge’ switch is released before ‘Fire’ |
| ELECTRIC FIRING: |
Requires sequenced 2 switch operation |
| CONTINUITY: |
Indicator immediately disengages during Charge/Fire operation |
| MECHANICAL |
| DIMENSION: |
3″wide x 2″thick x 6″high (7.6cmx 5cmx 15.2cm) |
| WEIGHT: |
18 oz w /battery (510g) |
| CASE MATERIAL: |
HD Urethane |
| HARDWARE: |
Brass, Nylon, Rubber |
| INGRESS: |
IP68 (3m) |
| OPERATING TEMP: |
Tested -20°F -140°F (-29°C -60°C ) |
| STORAGE TEMP: |
Tested -45°F -180°F (-42°C -82°C ) |
| COLORS: |
Black, Yellow, Tan, OD Green |
| POWER SOURCE |
| BATTERY: |
Replaceable 9V (HD alkaline recommended ) |
| LIFE: |
~250+ Charge/Fire Cycles typical |
| FEATURES |
| CONNECTION: |
EIT’s quick-connect HD Output Binding Posts |
| SWITCHES: |
Recessed & Guarded with rugged waterproof boots |
| BATTERY: |
Battery loads smoothly through side of unit and is secured in place by easy-on/off battery cap |
| WARRANTY: |
Lifetime warranty against manufacturing defects |