Item # 5028
Ideal Blasting Analog Blaster's Ohmmeter
MSHA Approved
Size
3"W x 1.5"D x 4"H
(7.6cm W x 3.81cm D x 10.13cm H)
Weight 10 oz. (.28kg)
To Operate:
Press and hold both ends of the blasting circuit to the terminals located on top of the WDRC. When a circuit is present, the unit will display the resistance of the attached blasting circuit represented in Ohms in the Display area. When finished reading resistance, remove blasting circuit ends from the terminals. Unit will power down automatically. To preserve battery life, insure that the unit is not stored with loose conductive material. NEVER use the WDRC to measure voltage or current. This meter ONLY measures and displays resistance. On State Only 'On' when Circuit Present
MSHA Approval No.: 2G34790